The lever arm used for plunging the foam was redesigned with a rigid connection to the base of the filter support. This rigid connection eliminates large movement in the z-direction and the need for guidance by the barrel lid on the 55-gallon drum. The open-top design allows for integration of the new CDC/LFOM design: influent raw water pours out of the LFOM and directly into the filter body.
Read more about what the foam filtration team hopes to accomplish through Future Research.