Numerical Solution

...

A second-order discretization scheme will be used to approximate the solution. In order to implement the second order scheme click on Solution Methods then click on Momentum and select Second Order Upwind as shown in the image below. 

...

Here, the flow field will be initialized to the values at the inlet. In order to carry out the initialization click on Solution Initialization, Standard Initialization, and click on Compute from and select inlet as shown below. 


Then, click the Initialize button,  . This completes the initialization.

...

FLUENT reports a residual for each governing equation being solved. The residual is a measure of how well the current solution satisfies the discrete form of each governing equation. We'll iterate the solution until the residual for each equation falls below 1e-6. In order to specify the residual criteria (Click) Monitors > Residuals > Edit..., as shown in the image below. 

...


Next, change the residual under Convergence Criterion for continuityx-velocity, and y-velocity, all to 1e-6, as can be seen below. 


Lastly, click OK to close the Residual Monitors menu.

Execute Calculation

Prior, to running the calculation the maximum number of iterations must be set. To specify the maximum number of iterations click on Run Calculation then set the Number of Iterations to 1000, as shown in the image below. 

...


As a safeguard save the project now. Now, click on Calculate two times in order to run the calculation. The residuals for each iteration are printed out as well as plotted in the graphics window as they are calculated. After running the calculation, you should obtain the following residual plot. 

...