Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Migrated to Confluence 4.0

...

for

...

information

...

on

...

sedimentation,

...

please

...

see

...

Plate

...

Settler

...

Spacing

...

Research

...

Fall

...

2008.

Schematic

Image Added

Click below for the following image.
Original System
Photo of Whole System

Schematic Map for the Setup
  • Bucket 1 has the concentrated clay that is being stirred. The concentration of the clay is 5 g/L.
  • Bucket 2: The gold labeled tube is used for monitoring the influent turbidity. The turbidity meter reads the turbidity and process controller switches the pinch valve on for 5 seconds and when the turbidity reading is less 100 NTU
  • The gold colored tubing indicates the water and clay mixture is going through Pump 1 to the turbidity meter to maintain a constant flow of 100 NTU influent water.
  • Blue labeled tubing indicates the main flow that leads to the ultimate goal: measuring the effluent turbidity. The light blue tubing goes from Bucket 2>>>Pump 3>>>Flocculator>>>Flou Blanket Column >>>to the Plate Settler Tubes >>>Turbidity Meter >>> Waste.
  • The Pressure Sensor in Bucket 2 is connected to the computer monitoring the water level in the bucket through process controller.
  • The blue tube from Bucket 2 shows the path of the water coming from the temperature controlled tank.
  • Pump 3 pumps the mixture from the blue tank to the flocculator. The single tube connected the blue bucket of mixed clay and water to the pump 3 is split into two just before the pump. This allows for desired flow rate of water to be pumped through the system. The required flow rate is 545mL/min and the maximum flow rate that can be produce by this pump is 300 mL/min. Therefore, the single tube is split into two which are pumped at 272 mL/min each.
  • The Alum Stock is where the Aluminum Sulfate is stored and mixed with the magnetic stirrer.
  • The purple tubing shows the flow of alum into the setup from the alum stock through Pump 4. It is mixed into the water and clay solution in the rapid mix section before entering Pump 3.
  • The Floc Blanket Column receives the water mixture from the bottom of the column. Water is pulled off the top of the column through the plate setters by pump 2, and rest is wasted.
  • The floc blanket in the column is control by the flow control weir.
  • The plate settling tubes are placed at sixty degrees with a metal splint that is fastened to the manifold of the plate settling tubes.
  • The flocculator is in a vertical position with two coiled cylinder. The mixture of clay, alum, and water is pumped into flocculator by Pump 3. After flocculation, the mixture flows into the column.
Pathways for each colored tubing:
  • Pink
    • Bucket 1 >>>>>Pinch Valve>>>>>Bucket 2
    • Inlet for the clay mixture into the Bucket 2 to mix with the water.
  • Red
    • Bucket 2>>>>>Waste
    • This tubing is used to control the water level in the bucket 2. Therefore, this tubing is essential to prevent flooding.
  • Cyan
    • Air>>>>>Bucket 2
    • This is the bubbling system for Bucket 2. The bubbler aid in the mixing of water and clay in Bucket 2.
  • Gold
    • Bucket 2>>>>>Pump 1>>>>> Turbidity Meter>>>>>Bucket 2
    • This tubing ensures that the flow in Bucket 2 is maintained at 100 NTU.
  • Purple
    • Alum Stock>>>>>Pump 4>>>>>Blue Tubing
    • The purple tubing shows how and where the alum is mixed into the system.
  • Blue
    • Water Tank>>>>>Bucket 2
    • This show how and where the water comes from.  This is essential to guarantee that there is water in the system.
  • Bright Green
    • Flocculator>>>>>Atmosphere
    • The tubing plays an important role to extract air bubbles from the flocculator and the system.
  • Jungle Green
    • Bucket 2>>>>>Computer
    • This tubing reads and records the pressure in Bucket 2. This measurement will assist the Control Process when to shut down to prevent problems to occur in the experiment.
  • Orange
    • Column>>>>>Flow Control Weir
    • Floc blanket control occurs here.
  • Light Blue
    • Bucket 2>>>>>Pump 3>>>>>Flocculator>>>>>Column>>>>>Settling Tubes>>>>>Manifold>>>>>Turbidity Meter>>>>>Pump 2>>>>>Waste
    • THIS IS THE MEASURING TUBING. This measuring tubing is vital to collecting data to investigate whether our design it is good or not to improve water condition.
Major Changes in Setup

The temperature controlled water tank that provides water to the system was originally sitting on the table top. The system was not getting enough water from controlled water source. The mixture tank would run out of water after the system was running for a long time. As a solution we decided to raise a tank to account for the head loss in the 3/8 in tube leading to the the mixture tank (labeled as bucket 2 in the schematic). After raising the water tank by fourteen inches, the mixture stop running low on water. Initially we performed a head loss calculation to determine the exact height the tank would need to be elevated, however the final height of 14 inches was more than enough and based on the materials available for elevating the tank(two cement blocks). From our observations and data, it was confirmed that raising the water tank was the right decision.
The second change was the addition of a rapid mix chamber. A small cylinder with 3 in diameter was used a base to coil a 1/4 in inner diameter tube. The addition of the rapid mix section was used to improve the mixing of the alum and dirty water prior to entering pump 3, which leads directly to the flocculator. Increasing the mixing allowed for more contact time between the alum and the suspended clay particles.
Aside from the additional cylinder, the flocculator was improved. To remove bubbles and prevent their formation, the flocculator was rotated into a vertical position. An in depth description of the design of the new flocculator can be found in the design parameters section (below).

Another change to the setup is the method used to control the floc blanket. Originally valve was used to control waste from 1/2 in ID tube connected to a bulk head approximately 20 cm from the top of the settle column. The would be partially or fully opened to regulate the height of the floc blanket. This method, however, was far from precise and the floc blanket level fluctuated. To end this fluctuation in the floc blanket level, a device called the flow control weir was attached. This flow control weir is joined by black tubing. Within this black tubing, the head loss occurred. By altering height of the flow control weir, the height of the floc blanket is shifted. Essentially, it had the same functions as the original method of opening the valve. However, this flow control weir controlled the height of the floc blanket better. This was proven by observations and data collected from each experiment. As a result, a stable floc blanket was achieved. It was also determined the floc blanket must be below the settling tubes for optimum effluent turbidity.

Apart from the floc blanket, the floc formation was improved by removing a mesh in the column. The initial setup had a mesh that was locked onto the top of the cone inside the column. For the improved setup, this mesh was removed to form larger flocs. Originally,as the floc formation improved, and larger flocs were formed, the mesh began to break up the larger flocs, which inhibited floc blanket formation. Without the presence of the mesh, it was observed that bigger flocs were formed.

A peristaltic pump was added to the system to allow independent alum flow control. The original concentration of the alum varied with the flow rate of the settling tubes. Even with the use of a smaller tubing size, the alum flow rate was relatively high and required lower concentrations. As a result, the alum stock was limited did not last more than 10 hours. This made it difficult to run the system for long periods of time. Instead for the sharing the same pump as the settling tubes, the alum stock utilized the additional pump. With this additional pump, the alum stock concentration was adjusted so that system could run for extended periods of time. The concentration was to 15 g/L for 4 liters tank. With this concentration and tank size, the alum stock could last for 1.68 days running at a flow rate of 1.67 mL/min.

In conclusion, the following major changes were made:

  1. Raised temperature controlled water tank by 14 in
  2. Added 1/4 in ID rapid mix tube around 3 in diameter cylinder before flocculator
  3. Changed the orientation of the floccultor to vertical
  4. Added flow control wier for floc blanket height
  5. Removal of the mesh above cone
  6. Added peristaltic pump for alum stock

Design Parameters

Flocculator design

The use of a tube flocculator allows for a more controlled flocculation environment as compared to flocculation with baffles. The flocculation design parameters are based on creating optimal conditions for floc blanket formation. The flow rate through the system of the original experimental apparatus was 9.1 mL/s. The following parameters described the original flocculator.

  • L: 17 m
  • d: 9.52 mm (3/8 in) (inner tube diameter)
  • Gs: 71.4 1/s (average velocity gradient if the tube were straight)
  • Gc: 82.6 1/s (average velocity gradient in the curved tube)
  • θ:125.4 s (residence time)
  • Gcθ: 11020

These values were found using the following equations:

Velocity Gradient

Wiki Markup
]._

h4. Schematic

!Plate Settler Spacing Research Fall 2008^Improved.jpg|width=600px!

Click below for the following image.
[Original System]
[Photo of Whole System]

h5. Schematic Map for the Setup

* Bucket 1 has the concentrated clay that is being stirred. The concentration of the clay is 5 g/L.
* Bucket 2: The gold labeled tube is used for monitoring the influent turbidity. The turbidity meter reads the turbidity and process controller switches the pinch valve on for 5 seconds and when the turbidity reading is less 100 NTU
* The gold colored tubing indicates the water and clay mixture is going through Pump 1 to the turbidity meter to maintain a constant flow of 100 NTU influent water.
* Blue labeled tubing indicates the main flow that leads to the ultimate goal: measuring the effluent turbidity. The light blue tubing goes from *Bucket 2>>>Pump 3>>>Flocculator>>>Flou Blanket Column >>>to the Plate Settler Tubes >>>Turbidity Meter >>> Waste.*
* The Pressure Sensor in Bucket 2 is connected to the computer monitoring the water level in the bucket through process controller.
* The blue tube from Bucket 2 shows the path of the water coming from the temperature controlled tank.
* Pump 3 pumps the mixture from the blue tank to the flocculator. The single tube connected the blue bucket of mixed clay and water to the pump 3 is split into two just before the pump. This allows for desired flow rate of water to be pumped through the system. The required flow rate is 545mL/min and the maximum flow rate that can be produce by this pump is 300 mL/min. Therefore, the single tube is split into two which are pumped at 272 mL/min each.
* The Alum Stock is where the Aluminum Sulfate is stored and mixed with the magnetic stirrer.
* The purple tubing shows the flow of alum into the setup from the alum stock through Pump 4. It is mixed into the water and clay solution in the rapid mix section before entering Pump 3.
* The Floc Blanket Column receives the water mixture from the bottom of the column. Water is pulled off the top of the column through the plate setters by pump 2, and rest is wasted.
* The floc blanket in the column is control by the flow control weir.
* The plate settling tubes are placed at sixty degrees with a metal splint that is fastened to the manifold of the plate settling tubes.
* The flocculator is in a vertical position with two coiled cylinder. The mixture of clay, alum, and water is pumped into flocculator by Pump 3. After flocculation, the mixture flows into the column.

h5. Pathways for each colored tubing:

* Pink
** *Bucket 1 >>>>>Pinch Valve>>>>>Bucket 2*
** Inlet for the clay mixture into the Bucket 2 to mix with the water.
* Red
** *Bucket 2>>>>>Waste*
** This tubing is used to control the water level in the bucket 2. Therefore, this tubing is essential to prevent flooding.
* Cyan
** *Air>>>>>Bucket 2*
** This is the bubbling system for Bucket 2. The bubbler aid in the mixing of water and clay in Bucket 2.
* Gold
** *Bucket 2>>>>>Pump 1>>>>> Turbidity Meter>>>>>Bucket 2*
** This tubing ensures that the flow in Bucket 2 is maintained at 100 NTU.
* Purple
** *Alum Stock>>>>>Pump 4>>>>>Blue Tubing*
** The purple tubing shows how and where the alum is mixed into the system.
* Blue
** *Water Tank>>>>>Bucket 2*
** This show how and where the water comes from.  This is essential to guarantee that there is water in the system.
* Bright Green
** *Flocculator>>>>>Atmosphere*
** The tubing plays an important role to extract air bubbles from the flocculator and the system.
* Jungle Green
** *Bucket 2>>>>>Computer*
** This tubing reads and records the pressure in Bucket 2. This measurement will assist the Control Process when to shut down to prevent problems to occur in the experiment.
* Orange
** *Column>>>>>Flow Control Weir*
** Floc blanket control occurs here.
* Light Blue
** *Bucket 2>>>>>Pump 3>>>>>Flocculator>>>>>Column>>>>>Settling Tubes>>>>>Manifold>>>>>Turbidity Meter>>>>>Pump 2>>>>>Waste*
** THIS IS THE MEASURING TUBING. This measuring tubing is vital to collecting data to investigate whether our design it is good or not to improve water condition.

h5. Major Changes in Setup

The temperature controlled water tank that provides water to the system was originally sitting on the table top. The system was not getting enough water from controlled water source. The mixture tank would run out of water after the system was running for a long time. As a solution we decided to raise a tank to account for the head loss in the 3/8 in tube leading to the the mixture tank (labeled as bucket 2 in the schematic). After raising the water tank by fourteen inches, the mixture stop running low on water. Initially we performed a head loss calculation to determine the exact height the tank would need to be elevated, however the final height of 14 inches was more than enough and based on the materials available for elevating the tank(two cement blocks). From our observations and data, it was confirmed that raising the water tank was the right decision.
The second change was the addition of a rapid mix chamber. A small cylinder with 3 in diameter was used a base to coil a 1/4 in inner diameter tube. The addition of the rapid mix section was used to improve the mixing of the alum and dirty water prior to entering pump 3, which leads directly to the flocculator. Increasing the mixing allowed for more contact time between the alum and the suspended clay particles.
Aside from the additional cylinder, the flocculator was improved. To remove bubbles and prevent their formation, the flocculator was rotated into a vertical position. An in depth description of the design of the new flocculator can be found in the design parameters section (below).

Another change to the setup is the method used to control the floc blanket. Originally valve was used to control waste from 1/2 in ID tube connected to a bulk head approximately 20 cm from the top of the settle column. The would be partially or fully opened to regulate the height of the floc blanket. This method, however, was far from precise and the floc blanket level fluctuated. To end this fluctuation in the floc blanket level, a device called the flow control weir was attached. This flow control weir is joined by black tubing. Within this black tubing, the head loss occurred. By altering height of the flow control weir, the height of the floc blanket is shifted. Essentially, it had the same functions as the original method of opening the valve. However, this flow control weir controlled the height of the floc blanket better. This was proven by observations and data collected from each experiment. As a result, a stable floc blanket was achieved. It was also determined the floc blanket must be below the settling tubes for optimum effluent turbidity.

Apart from the floc blanket, the floc formation was improved by removing a mesh in the column. The initial setup had a mesh that was locked onto the top of the cone inside the column. For the improved setup, this mesh was removed to form larger flocs. Originally,as the floc formation improved, and larger flocs were formed, the mesh began to break up the larger flocs, which inhibited floc blanket formation. Without the presence of the mesh, it was observed that bigger flocs were formed.

A peristaltic pump was added to the system to allow independent alum flow control. The original concentration of the alum varied with the flow rate of the settling tubes. Even with the use of a smaller tubing size, the alum flow rate was relatively high and required lower concentrations. As a result, the alum stock was limited did not last more than 10 hours. This made it difficult to run the system for long periods of time. Instead for the sharing the same pump as the settling tubes, the alum stock utilized the additional pump. With this additional pump, the alum stock concentration was adjusted so that system could run for extended periods of time. The concentration was to 15 g/L for 4 liters tank. With this concentration and tank size, the alum stock could last for 1.68 days running at a flow rate of 1.67 mL/min.

In conclusion, the following major changes were made:
 # Raised temperature controlled water tank by 14 in
 # Added 1/4 in ID rapid mix tube around 3 in diameter cylinder before flocculator
 # Changed the orientation of the floccultor to vertical
 # Added flow control wier for floc blanket height
 # Removal of the mesh above cone
 # Added peristaltic pump for alum stock

h4. Design Parameters


h5. Flocculator design

The use of a tube flocculator allows for a more controlled flocculation environment as compared to flocculation with baffles. The flocculation design parameters are based on creating optimal conditions for floc blanket formation. The flow rate through the system of the original experimental apparatus was 9.1 mL/s. The following parameters described the original flocculator.

* L: 17 m
* d: 9.52 mm (3/8 in) (inner tube diameter)
* Gs: 71.4 1/s (average velocity gradient if the tube were straight)
* Gc: 82.6 1/s (average velocity gradient in the curved tube)
* θ:125.4 s (residence time)
* Gcθ: 11020

These values were found using the following equations:

Velocity Gradient
{latex}
$$
G_s  = {{8Q} \over {3\pi r^3 }}
$$
{latex}

The

...

velocity

...

gradient

...

in

...

a

...

curved

...

tube

...

is

...

given

...

by

...

(Mishra

...

&

...

Gupta

...

1979)

Wiki Markup
 
{latex}$$
G_c  = G_s \left( {1 + 0.033\log \left( {De} \right)^4 } \right)^{{\raise0.7ex\hbox{$1$} \!\mathord{\left/
 {\vphantom {1 2}}\right.\kern-\nulldelimiterspace}
\!\lower0.7ex\hbox{$2$}}} 
$$ {latex}

Where

...

De

...

is

...

the

...

nondimensional

...

Dean

...

Number

...

and

...

characterizes

...

the

...

effect

...

of

...

curvature

...

on

...

fluid

...

flow:

Wiki Markup

{latex}
$$
De = \sqrt {{r \over {R_c }}} {\mathop{\rm Re}\nolimits} _d 
$$
{latex}

Residence Time

Wiki Markup
 Time
{latex}$$
\theta  = {L \over V}
$${latex}


Several

...

flocculator

...

designs

...

were

...

used

...

in

...

the

...

trial

...

runs

...

of

...

the

...

experiment.

...

The

...

initial

...

flocculator

...

was

...

oriented

...

horizontally

...

across

...

the

...

work

...

bench.

...

This

...

orientation

...

led

...

to

...

a

...

numerous

...

small

...

bubbles

...

trapped

...

throughout

...

the

...

system.

...

It

...

also

...

made

...

the

...

flocculator

...

difficult

...

to

...

fill.

...

The

...

first

...

change

...

therefore,

...

was

...

to

...

use

...

a

...

vertical

...

flocculator

...

orientation.

...

This

...

allowed

...

bubbles

...

in

...

the

...

flocculator

...

to

...

flow

...

upwards

...

towards

...

the

...

top

...

where

...

a

...

tee

...

and

...

vertical

...

tube

...

open

...

to

...

the

...

atmosphere

...

released

...

any

...

bubbles

...

in

...

the

...

flocculator.

...

Upon

...

observation,

...

it

...

was

...

clear

...

that

...

the

...

flocs

...

being

...

produced

...

in

...

the

...

flocculator

...

were

...

too

...

small.

...

It

...

was

...

originally

...

thought

...

that

...

this

...

was

...

due

...

to

...

the

...

high

...

flow

...

rate

...

through

...

the

...

system.

...

Again

...

the

...

flow

...

rate

...

through

...

the

...

flocculator

...

is

...

based

...

on

...

an

...

upflow

...

velocity

...

of

...

100m/day

...

for

...

proper

...

floc

...

blanket

...

formation

...

in

...

the

...

settling

...

column.

...

The

...

flow

...

rate

...

was

...

then

...

halved

...

by

...

adding

...

another

...

flocculator.

...

Since

...

the

...

flow

...

through

...

pump

...

3

...

was

...

already

...

split

...

this

...

was

...

adjustment

...

was

...

quite

...

simple.

...

Each

...

of

...

the

...

split

...

flows

...

were

...

led

...

directly

...

to

...

a

...

flocculator.

...

The

...

flow

...

out

...

of

...

the

...

flocculator

...

was

...

then

...

joined

...

into

...

a

...

single

...

tube

...

flowing

...

into

...

the

...

settling

...

column

...

using

...

a

...

tee.

...

After

...

these

...

adjustments

...

floc

...

formation

...

was

...

still

...

less

...

than

...

satisfactory,

...

with

...

the

...

average

...

floc

...

size

...

in

...

the

...

flocculators

...

observed

...

as

...

less

...

than

...

1

...

mm.

...

It

...

was

...

later

...

noted

...

that

...

the

...

combining

...

of

...

the

...

two

...

flows

...

(each

...

with

...

a

...

flow

...

rate

...

of

...

approximately

...

272

...

mL/min)

...

created

...

shear

...

valves

...

far

...

exceeding

...

the

...

average

...

shear

...

values

...

in

...

the

...

flocculators

...

(71.4

...

/s),

...

which

...

likely

...

resulted

...

in

...

the

...

breaking

...

up

...

of

...

flocs

...

formed

...

in

...

the

...

two

...

flocculators.

...

It

...

is

...

important

...

to

...

note

...

that

...

the

...

system

...

was

...

producing

...

a

...

floc

...

blanket,

...

however,

...

it

...

was

...

not

...

very

...

dense

...

and

...

the

...

effluent

...

turbidities

...

were

...

still

...

quite

...

high.

...

Current

...

design

...

The

...

current

...

flocculator

...

set-up

...

contains

...

one

...

continuous

...

flocculator

...

placed

...

on

...

two

...

adjacent

...

columns.

...

The

...

flow

...

rate

...

through

...

the

...

system

...

remains

...

at

...

545

...

mL/min,

...

however,

...

the

...

length

...

of

...

the

...

flocculator

...

has

...

increased

...

to

...

27

...

m.

...

As

...

seen

...

in

...

the

...

schematic

...

above

...

there

...

are

...

now

...

two

...

flocculator

...

columns

...

with

...

the

...

water

...

spiraling

...

upward

...

to

...

the

...

top

...

of

...

the

...

first

...

flocculator

...

where

...

there

...

is

...

the

...

first

...

bubble

...

release

...

T-connector.

...

The

...

flow

...

then

...

crosses

...

over

...

to

...

the

...

top

...

of

...

the

...

second

...

column

...

where

...

it

...

spirals

...

downward

...

reaching

...

another

...

bubble

...

release

...

t-joint

...

right

...

before

...

heading

...

into

...

the

...

bottom

...

of

...

the

...

settling

...

column.

...

The

...

increased

...

residence

...

time

...

in

...

the

...

system

...

allows

...

for

...

larger

...

floc

...

formation,

...

and

...

an

...

increase

...

in

...

the

...

total

...

number

...

flocs

...

forming

...

in

...

the

...

flocculator.

...

Improved

...

floc

...

formation

...

allows

...

for

...

the

...

formation

...

denser

...

floc

...

blankets.

...

Final

...

flocculator

...

parameters

...

(see

...

curved tube

...

flocculator

...

design.xmcd

...

)

...

  • d:

...

  • 9.52

...

  • mm

...

  • (3/8

...

  • in)

...

  • *

...

  • Q:

...

  • 9.1

...

  • mL/s

...

  • *

...

  • Gs:

...

  • 71.4

...

  • 1/s

...

  • *note

...

  • these

...

  • parameters

...

  • stayed

...

  • the

...

  • same

...

  • Gc:

...

  • 82.6

...

  • 1/s

...

  • (average

...

  • velocity

...

  • gradient

...

  • in

...

  • the

...

  • curved

...

  • tube)

...

  • L:

...

  • 27

...

  • m

...

  • θ:

...

  • 212

...

  • s

...

  • Gθ:

...

  • 17500

...

The

...

high

...

G

...

value

...

and

...

long

...

residence

...

time

...

helps

...

create

...

the

...

large

...

amount

...

of

...

flocs

...

needed

...

for

...

the

...

initial

...

formation

...

of

...

the

...

floc

...

blanket.

...

The

...

flow

...

rate

...

through

...

the

...

flocculator

...

(9.1

...

mL/s)

...

is

...

generated

...

by

...

two

...

equal

...

flows

...

of

...

4.54

...

mL/s,

...

based

...

on

...

the

...

maximum

...

flow

...

through

...

the

...

peristaltic

...

pumps.

...

There

...

are

...

still

...

some

...

improvements

...

to

...

be

...

made

...

to

...

the

...

flocculator.

...

Suggestions

...

for

...

improvement

...

are

...

discussed

...

in

...

the

...

future

...

goals section

Uniform Flow
Wiki Markup
 section|Plate Settler Spacing Spring 2009 Challenges]

h5. Uniform Flow

{float:right|border=2px solid black}
!Plate Settler Spacing Research Fall 2008^Uniformflow.png|width=250px!
{float}

Uniform

...

flow

...

in

...

the

...

settling

...

column

...

is

...

key

...

for

...

having

...

laminar

...

flow

...

in

...

the

...

tube

...

settlers

...

as

...

well

...

as

...

the

...

creation

...

of

...

the

...

floc

...

blanket.

...

As

...

seen

...

in

...

the

...

image

...

to

...

the

...

right,

...

a

...

uniform

...

flow

...

is

...

needed

...

at

...

the

...

inlet

...

of

...

the

...

settling

...

tube

...

so

...

the

...

flow

...

becomes

...

laminar

...

before

...

reaching

...

the

...

end

...

of

...

the

...

tube.

...

All

...

design

...

assumptions

...

and

...

parameters

...

for

...

the

...

column

...

are

...

based

...

on

...

a

...

laminar

...

flow

...

through

...

the

...

settling

...

tubes.

...

Flow

...

in

...

to

...

the

...

system

...

from

...

the

...

bottom

...

of

...

the

...

settling

...

column

...

creates

...

a

...

jet

...

in

...

the

...

center

...

of

...

the

...

column,

...

which

...

is

...

far

...

from

...

uniform

...

flow.

...

A

...

typical

...

dissipation

...

ratio

...

is

...

1:10;

...

therefore,

...

it

...

would

...

take

...

on

...

the

...

order

...

of

...

10

...

m

...

for

...

jet

...

to

...

dissipate

...

in

...

a

...

column

...

with

...

a

...

diameter

...

10

...

cm,

...

as

...

in

...

the

...

current

...

setup.

...

A

...

cone

...

with

...

a

...

ratio

...

of

...

4:6

...

is

...

used

...

a

...

diffuse

...

to

...

maximize

...

the

...

lateral

...

spread

...

of

...

the

...

jet.

...

In

...

addition

...

to

...

the

...

cone,

...

there

...

is

...

a

...

mesh

...

directly

...

on

...

top

...

of

...

the

...

cone

...

made

...

of

...

a

...

1

...

cm

...

thick

...

plastic

...

sheet

...

with

...

uniformly

...

distributed

...

holes

...

of

...

0.5

...

cm

...

diameter.

...

The

...

purpose

...

of

...

the

...

mesh

...

is

...

to

...

break

...

up

...

the

...

single

...

jet

...

coming

...

from

...

the

...

column

...

inlet

...

into

...

several

...

smaller,

...

weaker

...

jets

...

that

...

dissipate

...

quicker.

...

The

...

preliminary

...

stages

...

of

...

the

...

experiment

...

tested

...

the

...

effectiveness

...

of

...

the

...

cone

...

and

...

mesh

...

system

...

in

...

dissipating

...

the

...

jet

...

and

...

allowing

...

for

...

optimal

...

floc

...

blanket

...

formation

...

and

...

maintenance.

...

The

...

mesh

...

was

...

eventually

...

removed

...

due

...

the

...

breaking

...

up

...

of

...

flocs.

...

Further

...

discussion

...

about

...

testing

...

the

...

effectiveness

...

of

...

the

...

mesh

...

can

...

be

...

found

...

in

...

the

...

future

...

work

...

section.

...

Based

...

on

...

the

...

allowable

...

space

...

in

...

the

...

settling

...

column

...

the

...

floc

...

blanket

...

height

...

will

...

be

...

no

...

more

...

than

...

60

...

cm.

...

The

...

alum

...

dosage

...

of

...

45

...

mg/L

...

is

...

also

...

important

...

for

...

the

...

creation

...

of

...

the

...

floc

...

blanket.

...

In

...

previous

...

experiments

...

it

...

was

...

thought

...

that

...

45

...

mg/L

...

was

...

too

...

high

...

increasing

...

the

...

"stickiness"

...

of

...

the

...

tube

...

settlers

...

and

...

leading

...

to

...

clogging.

...

The

...

same

...

chemical

...

properties

...

of

...

the

...

aluminum

...

sulfate

...

actually

...

aid

...

in

...

the

...

creation

...

and

...

maintenance

...

of

...

the

...

floc

...

blanket,

...

creating

...

a

...

stick

...

mesh

...

of

...

suspended

...

flocs.

...

Objectives

The goal of the plate settler spacing team is to develop a more complete understanding of the effects of plate settler spacing on the sedimentation process. We seek to purify turbid water as efficiently as possible by optimizing materials and minimizing costs. Currently, our experiments vary the inner-diameter of the tube settlers. Ultimately, we will explore the interdependency of floc blanket depth, flow rates, and tube settler inner diameter.

References

Mishra, P. and Gupta, S. N. (1979) Momentum Transfer in Curved Pipes. 1. Newtonian Fluids. Industrial & Engineering Chemistry Process Design and Development 18(1), 130-137.