Chemical Doser Design

Wiki Markup
h1. Chemical Doser Design
{float:right|border=2px solid black|width=260px}
[!Laboratory Research Set-ups^Labeled Robust ACD freestanding F08 2.JPG|width=260px!|Laboratory Research Set-ups]
{float}

The

...

chemical

...

doser

...

(CD)

...

has

...

three

...

principle

...

components:

...

a

...

float,

...

a

...

lever

...

arm,

...

and

...

a

...

flow

...

controller

...

(FC).

...

The

...

float

...

currently

...

used

...

in

...

the

...

lab

...

for

...

data

...

collection

...

is

...

a

...

45.5

...

cm

...

long

...

4

...

in

...

PVC

...

tube

...

capped

...

at

...

both

...

ends

...

and

...

partially

...

filled

...

with

...

sand

...

so

...

that

...

it

...

weighs

...

8

...

lbs.

...

It

...

rests

...

33.5

...

cm

...

below

...

and

...

12

...

cm

...

above

...

the

...

water

...

line

...

in

...

a

...

virtual

...

grit

...

chamber,

...

which

...

is

...

a

...

deep

...

bucket

...

with

...

a

...

pressure

...

sensor

...

at

...

its

...

base.

...

This

...

pressure

...

sensor

...

provides

...

readings

...

of

...

the

...

water

...

level

...

in

...

the

...

bucket.

...

The

...

float

...

is

...

connected

...

via

...

low-elasticity

...

fishing

...

line

...

to

...

the

...

lever

...

arm.

...

The

...

lever

...

arm

...

is

...

a

...

68

...

cm

...

length

...

of

...

1

...

1/4

...

in

...

schedule

...

40

...

PVC

...

pipe

...

with

...

a

...

pivot

...

point

...

at

...

34

...

cm

...

(the

...

center).

...

Opposite

...

of

...

the

...

pivot

...

there

...

are

...

notches

...

cut

...

into

...

the

...

pipe

...

at

...

5

...

cm

...

length

...

intervals.

...

The

...

chemical

...

doser

...

hangs

...

from

...

these

...

notches.

...


A

...

1

...

1/2

...

in

...

schedule

...

40

...

PVC

...

pipe

...

attached

...

to

...

a

...

flange

...

base

...

holds

...

up

...

the

...

lever

...

arm.

...

Wiki Markup
{float:left|border=2px solid black|width=260px}
[!Laboratory Research Set-ups^IMG_7246.JPG|width=260px!|Laboratory Research Set-ups]
{float}

...


The

...

top

...

of

...

the

...

pipe

...

is

...

cut

...

in

...

a

...

saddle

...

shape

...

to

...

fit

...

the

...

lever

...

arm

...

through

...

it

...

and

...

create

...

the

...

pivot.

...

The

...

height

...

of

...

this

...

base

...

pipe

...

depends

...

on

...

the

...

design

...

constraints

...

of

...

the

...

plant

...

it

...

will

...

be

...

built

...

for.

...

The

...

FC

...

should

...

be

...

attached

...

to

...

the

...

base

...

pipe

...

with

...

two

...

clamps

...

that

...

are

...

interconnected

...

so

...

that

...

they

...

firmly

...

anchor

...

the

...

FC

...

at

...

the

...

appropriate

...

height

...

for

...

zeroing

...

the

...

CD

...

.

...

Only

...

one

...

clamp

...

was

...

used

...

during

...

experimental

...

testing

...

because

...

the

...

FC

...

was

...

being

...

continually

...

checked

...

and

...

re-zeroed,

...

and

...

it

...

was

...

being

...

used

...

in

...

a

...

very

...

controlled

...

environment.

...

Additional

...

clamps

...

would

...

be

...

necessary

...

for

...

robust

...

plant

...

operation.


Wiki Markup


\\

{float:right|border=2px solid black|width=260px}
[!Laboratory Research Set-ups^IMG_7243.JPG|width=260px!|Laboratory Research Set-ups]
{float}

The

...

chemical

...

dosing

...

tube

...

is

...

a

...

tube

...

with

...

an

...

open

...

T

...

connection

...

at

...

the

...

top,

...

which

...

allows

...

the

...

FC

...

outflow

...

tubing

...

to

...

drain

...

through

...

a

...

pressure

...

break

...

T.

...

The

...

tubing

...

exiting

...

the

...

pressure

...

break

...

T

...

has

...

a

...

larger

...

diameter

...

than

...

the

...

tubing

...

entering

...

it.

...

The

...

pressure

...

break

...

and

...

larger

...

outflow

...

tubing

...

allow

...

a

...

free

...

surface

...

at

...

the

...

same

...

height

...

as

...

the

...

discharge

...

to

...

the

...

rapid

...

mix

...

(minus

...

head

...

loss)

...

to

...

form

...

inside

...

the

...

larger

...

tube

...

while

...

air

...

can

...

also

...

flow

...

through

...

the

...

tube.

...

Currently

...

¼

...

inch

...

outer

...

diameter

...

tubing

...

is

...

used

...

to

...

connect

...

the

...

flow

...

controller

...

to

...

the

...

pressure

...

break

...

T,

...

but

...

it

...

is

...

not

...

known

...

what

...

size

...

tubing

...

is

...

necessary

...

to

...

allow

...

air

...

to

...

flow

...

after

...

the

...

T.

...

Experience

...

has

...

indicated

...

that

...

½

...

inch

...

outer

...

diameter

...

tubing

...

is

...

large

...

enough,

...

but

...

it

...

is

...

possible

...

that

...

tubing

...

with

...

an

...

outer

...

diameter

...

as

...

small

...

as

...

3/8

...

inch

...

could

...

work

...

as

...

well.

...

The

...

larger

...

tube

...

is

...

then

...

connected

...

to

...

1/4

...

in

...

outer

...

diameter

...

tubing,

...

which

...

connects

...

the

...

CD

...

to

...

the

...

rapid

...

mix.

...

It

...

is

...

unclear

...

if

...

this

...

final

...

connection

...

is

...

needed,

...

though,

...

and

...

it

...

may

...

be

...

removed

...

so

...

that

...

the

...

larger

...

tubing

...

connects

...

the

...

T

...

to

...

the

...

rapid

...

mix

...

directly.

...

For

...

laboratory

...

testing,

...

water

...

flows

...

from

...

the

...

bottom

...

of

...

the

...

chemical

...

dosing

...

tube

...

to

...

a

...

plastic

...

column

...

with

...

a

...

pressure

...

sensor

...

at

...

the

...

bottom.

...

This

...

pressure

...

sensor

...

gives

...

readings

...

of

...

water

...

height

...

in

...

the

...

column,

...

which

...

can

...

be

...

converted

...

into

...

flow

...

rates

...

from

...

the

...