Include Page | ||||
---|---|---|---|---|
|
Pre-
...
Analysis & Start-Up
Pre-Analysis
We must first calculate the theoretical critical buckling load of the column.
Where:
...
Therefore, our critical buckling load is = 1.51398E+7 N
Start-Up
Please look at the video located in the geometry section for the start-up step of this tutorial.
Go to Step 2: Geometry
...