To set up a camera it is necessary to make sure that the camera is only being used by one application at a time. Thus if Process Controller is configured to be using the Camera it is absolutely necessary to first disable that external function by setting it to constant intead of to variable or simply quit Process Controller. Then open Camera Configure.exe from the ProCoDA folder in program folder.

The Configure Camera application allows you to select which camera to use, to configure the video rate and image size, and depending on the camera to configure other camera settings. For many of our applications high resolution images will not be needed. I recommend using 480x640 images at 30 frames per second to detect floc water interface. You can