  • Worked to produce designs for a Ram Pump testing apparatus. Designs include wasted water collection and return as well as pumped water collection, measurement, and return.
  • Helped design an orifice flow meter that is easy to integrate into a 1" schedule 40 piping system and is monitored by process controller. The design process included matlab simulations of the meter to decide the optimal orifice size based on expected flow rates.
  • Helped to design a check valve that has an adjustable closing point based on the velocity of water flowing past it and adjustable stroke length.
  • Helped to build testing set up including 80/20 framing for pump mount, pipe supports, plumbing, and pump body.