1. Pre-Analysis & Start-Up

Solution Domain

For an external flow problem like this, one needs to determine where to place the outer boundary. A circular domain will be used for this simulation. The effects that the cylinder has on the flow extend far. Thus, the outer boundary will be set to be 64 times as large as the diameter of the cylinder. That is, the outer boundary will be a circle with a diameter of 64 m.

...