Fall 2010 Foam Filtration Research

Foam Filtration Unit Design

This filtration unit design should be optimized according to the required surface area and filtration velocity parameters determined through previous laboratory experiments. In addition, it should minimize the required plan area, as well as maximize the ease of maintenance for the operator.

Head Loss Calculation

The amount of headloss that occurs with the build up of particles in the foam will determine how often the filter will require cleaning, and the additional height required for the walls of the filtration unit to accomodate this additional head loss. It is therefore important to measure the change in headloss over the running time of the filter.

...

Thus far, filter performance has been tested using 5 NTU water. A variety of influent turbidities must be tested to determine the range the filter performs under EPA standards of 0.3 NTU.

Foam Filtration Unit Design