2) Develop a MATHCAD file that generates backwash and filtration design parameters
We needed this for both an actual AguaClara plant and a bench-scale or pilot plant model of the plant for testing.
MATHCAD File and description.

3) Experiments of bench-scale model to confirm design success
Bench scale modeling tests the effectiveness of a filtration design by shrinking the design parameters of the system (filter bed depth, filter bed surface area, and etc) to a smaller scale that is easier to test. For example, we would simulated a filter bed of 50 cm of sand with 5 cm of sand with the porosity and specific gravity of the sand being constant. This would also enable us to test the validity of the empirical equations that are behind our design.

...