h1. Sedimentation Drain Design


h3. Drain Sizing

The time it takes to drain the sed tank can be approximated by:
\\
{latex}
\large
$$
desiredT = {{16W_{SedBay} \^{1.5} \tan (AN_{SedPlate} )^{0.5} L_{Sed} } \over {3\pi D_{Valve} \^2 \sqrt {2g} }} + {{\sqrt {HW_{Sed} }  - \sqrt {{{W_{SedBay} } \over 2}\tan (AN_{SedPlate} )} } \over {{{\pi D_{Valve} \^2 } \over {8L_{Sed} W_{SedBay} }}\sqrt {{{2g} \over {Pi_{VenaContractaOrifice} }}} }}
$$

{latex}
\\
where W{~}SedBay~ is the width of a single sedimentation bay, AN{~}SedPlate~ is the angle of the bottom slopes from the horizontal, L{~}Sed~ is the length of the sedimentation tank, D{~}Valve~ is the diameter of the drain valve, HW{~}Sed~ is the water height in the sedimentation tank, and Pi{~}VenaContractaOrifice~ is the head loss through the valve.

A function to determine the valve diameter iterates from the smallest possible diameter to the largest diameter, calculating the respective drain times using the time function. The valve diameter function returns the smallest diameter that allows the sedimentation tank to drain  within the  time defined by the user. The iteration stops once a time no greater thanthe calculated diameter drains the sedimentation tank at least as fast as the desired time.

h3. Couplings

The calculated nominal valve diameter is thethat inner diameter of the slip side of the adapter, and is used to calculate the its inner and outer diameters. The outer diameter of the slip side.  The nominal diameter is also the is also the inner diameter of the threaded side. The outer diameter onof the threaded side whichis will be used as the inner diameter forof the valve thatwhich fits it.

!sed w couplings.bmp|width=958,height=750!

h3. Drain Slopes

Since the center of the valve is aligned with the floor of the sedimentation tank, slopes are required in the floor of the tank. The slopes have a width equal to the diameter of the valve and a depth equal to half the diameter (placing the center of the valve at-grade) with a slope of 30 degrees.

!sed w slopes.bmp|width=908,height=758! 

h3. Gate Valves

Gate valves are placed in every bay of every sedimentation tank at-grade to allow for draining.

!sed w valves.bmp|width=953,height=741!