In the current design, we have two circular orifices on the same pipe segment. Originally, the micro-mixing orifice was after the first pipe bend. However we have decided to change that to allow facility of removal when cleaning is required. The micro-mixing orifice is two pipe diameters below the macro-mixing orifice. This ensures adequate mixing time for macro-mixing to take effect. The orifices for both equations are sized using the equations of minor loss coefficient for a submerged orifice.
Wiki Markup |
---|
\\
% MathType\!MTEF\!2\!1\!+\-
% feaaguart1ev2aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn
% hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr
% 4rNCHbGeaGqiVCI8FfYJH8YrFfeuY-Hhbbf9v8qqaqFr0xc9pk0xbb
% a9q8WqFfeaY-biLkVcLq-JHqpepeea0-as0Fb9pgeaYRXxe9vr0-vr
% 0-vqpWqaaeaabiGaciaacaqabeaadaqaaqaaaOqaaiaadUeadaWgaa
% WcbaGaamyzaiaad+gacaWGYbGaamyAaiaadAgacaWGPbGaam4yaiaa
% dwgaaeqaaOGaeyypa0ZaaeWaaeaadaWcaaqaaiaadsgadaWgaaWcba
% GaamiCaiaadMgacaWGWbGaamyzaaqabaGcdaahaaWcbeqaaiaaikda
% aaaakeaacaWGlbWaaSbaaSqaaiaadAhacaWGJbaabeaakiaadsgada
% WgaaWcbaGaam4BaiaadkhaaeqaaOWaaWbaaSqabeaacaaIYaaaaaaa
% kiabgkHiTiaaigdaaiaawIcacaGLPaaaaaa\!4F5C\!
\[{K_{eorifice}} = \left( {\frac{{{d_{pipe}}^2}}{{{K_{vc}}{d_{or}}^2}} - 1} \right)\] |
Where:
K.e.orifice: Minor loss Coefficient
K.vc: Vena Contracta Coefficient
d.pipe: Pipe Inner Diameter
d.orifice: Orifice Diameter
...