Varying Alum

In the experiment, to investigate alum dosage at a given turbidity and length, we first planned to vary the alum dose over a large range, incrementing the dose in set intervals while holding the plant flow rate (shear), influent turbidity, and residence time constant.

Table 1 shows the alum ranges we tested for each flocculator length and influent turbidity:

TABLE 1: Alum dose ranges tested and the increment used (mg/L).

Flocculator Length (m)

5 NTU

25 NTU

50 NTU

100 NTU

500 NTU

28

10-50

10-50

10-66

20-60

10-90

Interval

5

5

7

5

10

56

10-50

10-50

10-66

20-60

10-90

Interval

5

5

7

5

10

84

10-50

10-50

10-66

20-60

10-90

Interval

5

5

7

5

10

The alum dose was varied in process controller using the increment function shown in Figure 1:
Image Added
FIGURE 1: Process Controller setpoints used to vary the alum dose.