Varying Alum
In the experiment, to investigate alum dosage at a given turbidity and length, we first planned to vary the alum dose over a large range, incrementing the dose in set intervals while holding the plant flow rate (shear), influent turbidity, and residence time constant.
Table 1 shows the alum ranges we tested for each flocculator length and influent turbidity:
TABLE 1: Alum dose ranges tested and the increment used (mg/L).
Flocculator Length (m) | 5 NTU | 25 NTU | 50 NTU | 100 NTU | 500 NTU |
---|---|---|---|---|---|
28 | 10-50 | 10-50 | 10-66 | 20-60 | 10-90 |
Interval | 5 | 5 | 7 | 5 | 10 |
56 | 10-50 | 10-50 | 10-66 | 20-60 | 10-90 |
Interval | 5 | 5 | 7 | 5 | 10 |
84 | 10-50 | 10-50 | 10-66 | 20-60 | 10-90 |
Interval | 5 | 5 | 7 | 5 | 10 |
The alum dose was varied in process controller using the increment function shown in Figure 1:
FIGURE 1: Process Controller setpoints used to vary the alum dose.