As expected, the effluent turbidity is much higher than that of the control experiment. The presence of saturated water in the influent has a very clear negative effect on the effluent turbidity. The bubbles released as a result of a pressure drop in the system disturbed floc formation, allowing less floc particles to settle and more, smaller, lighter particles to leave with the effluent. The occasional spikes in the data represent an air bubble floating up through the settler which creates a temporary spike in the turbidity.

Experiment 2: Effluent Turbidity v Time - High Floc Blanket Formation

During Experiment 2, the following velocities were used: 5 m/day, 10 m/day, 15 m/day and 20 m/day. This experiment was set on high floc blanket formation.

_Figure 1: Log(Effluent Turbidity) vs. Time_

Conclusion

Like the data collected for the floc blanket on low, the turbidity for the floc blanket on high is much higher as compared to the control experiment. The spikes in the turbidity represent an air bubble floating through the plate settler creating a temporary elevated turbidity