h1. Nonlinear Chemical Dose Controller Fall 2008-Summer 2009



 
h2. AbstractOverview
{float:right|border=2px solid black|width=400px}
!Non-linear CDC Design1XXX.jpg|width=400px,align=top!
h5. Figure 1: Draft nonlinear chemical dose controller design.
{float}


The nonlinear chemical dose controller (CDC) is designedh3.Abstract
Accurate alum dosing is vital for turbulentplant chemicaloperation doseas flowit rateshas toa begreat usedimpact inon conjunctionflocculation withand thethus [Rapidalso Mixon Chambersedimentation. DesignThe |Rapidnonlinear Mixchemical Chamberdose Design Program] in contrast to the [linear CDC| Linear Chemical Doser] which requires that the controller (CDC) is designed for turbulent chemical dose flow rates to be used in conjunction with the newly designed [Rapid Mix Tube| Rapid Mix Tube] in contrast to the [linear CDC| Linear Chemical Doser] which requires that the chemical flow in the dosing tube be laminar. The linear CDC uses the relationship between laminar flow and major losses in the doser tube to maintain a constant chemical dose with varying plant flow rates. However, when the flow in the dosing tube is turbulent, the linear relationship no longer exists. In this case, a nonlinear CDC, one that uses a combination of major and minor losses to control flow rates, can be used to maintain a constant chemical dose with the varying plant flow rates. By using an orifice to control chemical flow, the CDC will have the same nonlinear response to increasing flow as the plant flow rate which is controlled by a rectangular orifice. A float[dual inscale the system| Dual Scale System] on the lever arm will increase accuracy in dosing at smaller doses. 
A float in the entrance tank controls the height of a lever arm.  The dosing orifice is located at the opposite end of the leverdosing armtube. As plant flow rates increase, the float rises, and the dosing orifice falls making more head available to power chemical flow. As the flow rate decreases so does the available head and the chemical flow rate slows down. The lever arm has holes drilled into the top of it so that the dosing orifice may be inserted into one of these holes to adjust dosage for changes in turbidity. Since the dosing orifice flows directly into the lever arm, the alum will always be dispersed into the same spot, no matter the dose.


Theh3. advantageIntroduction to designing a nonlinear CDC is that higher chemical flow rates can be used. With an alum stock solution of 500 g/Land Objectives

As the AguaClara project grows, larger plants are being designed. These larger plants have a greater flow rate and thus there is a need for the linear flowdose controller canto deliverbe aredesigned maximumfor chemicalaccurate dosedosing offor 90 mg/L to plants withthese higher flow rates. asThe highNon-linear asDose 2000 L/min. In larger water treatment plants higher chemical flow rates are necessary to dose alum and chlorine. A flow controller with a higher capacity than the linear CDC flow controller is necessary for the nonlinear CDC. Head loss through the float valve orifice limits the [Flow Controller] to chemical flows less than 400 mL/min. Otherwise; the chemical stock tank needs to be placed excessively far above the flow controller float valve. This maximum chemical flow is adequate for [La 34], [Ojojona], [Tamara], and [Cuatro Comunidades] given their flow rates. Two flow controllers working in parallel are used to achieve the necessary alum dose at [Marcala]. As the demand for larger AguaClara plants grows, larger chemical flow rates will be required. Controller Team is working on redesigning the dose controller, including the flow controller, the doser, and the flow measurement device. We are also working on designing the rapid mix tube for large-scale and small-scale mixing. 

After the new design is completed, the non-linear dose controller will be constructed. Experiments will be done to verify the accuracy of the dose controller compared to theoretical results. This new design will be presented at the EPA's P3 competition in Spring 2010 for the Phase II prize of $75,000. The design will also be implemented at the [new Agalteca plant| Agalteca] in Honduras. 

"Non-Linear Chemical Dose Controller Fall 2009"  [Goals| CDC Detailed Task List Fall 2009] and [Meeting Minutes| CDC Meeting Minutes Fall 2009]


h3. Theory
The nonlinear doser uses a dosing orifice (minor losses) instead of a dosing tube (major losses) to control the relationship between changing plant flow rates and chemical dose. The flow rate through the CDC is related to the available head by the equation:

{latex}$$Q_{Cdc}  = K_{orifice}\sqrt {2gh_{Cdc} } $${latex}

where
* {latex}$$Q_{Cdc} $${latex} is the chemical flow rate
* {latex}$$ K_{orifice} $${latex} is the orifice coefficient
* h is the available head 

The chemical entrancedose to the rapidplant can mixbe tankdetermined isby a rectangularsimple orifice. The relationship between flow rate and head is governed by the equationmass balance:

{latex}$$ Q_{Plant}$$C_p  = K {{C_c Q_{orificeCdc} } \sqrtover {2ghQ_{EtOrificePlant} } }$${latex}

where
* {latex}$$ Q_{Plant}$${latex}  C ~c~ is the plantchemical flowstock rateconcentration
* {latex}$$ h_{EtOrifice} $${latex} C ~p~ is the height ofchemical dose

The water aboveleaves the entrance tank orfice

The chemical dose to the plant can be determined by a simple mass balance:

{latex}$$C_p  = {{C_c Q_{Cdc} } \over {Q_{Plant} }}$${latex}

where
* C ~c~ is the chemical stock concentration
* C ~p~ is the chemical dose

The CDC uses a lever arm to relate head above the centerline of the rectangular plant entrance orifice to head in the dosing orifice. This means that the available head for the dosing orifice is the same as the head controlling the plant flow rate. The increase in head links the chemical flow rate to the plant flow rate and the chemical dose will be constant as plant flow varies as long as the exponent of the head is the same for both the plant flow and the chemical flow.

The dosing tube must be designed to minimize major losses so that the major losses that deviate from the {latex}$$V = \sqrt {2gh}$${latex} relationship do not cause excessive errors. The deviation from {latex}$$V = \sqrt {2gh}$${latex} is especially significant when the flow through the dosing tube becomes laminar. The dosing tube must be flexible to accommodate the lever arm motion and dose adjustment. The flow conduit used to transport the chemical flow from the orifice to the place where it is mixed with the plant flow must still be designed. The flow conduit must be designed such that the pressure is atmospheric at the exit of the dose control orifice.


h3. Methods

h4. Flexible Dosing Tube

The dosing tube diameter is based on the minimum available diameter that will have a head loss less than the given fraction of the maximum CDC head loss under conditions of the maximum chemical flow rate. 

h4. Dosing Orifice

The dosing orifice is designed to produce the difference in head loss between the maximum CDC head loss and the actual head loss in the flexible dosing tube:

{latex}$$
h_l  = K_{DoseOrifice} {{V_{DoseTube}^2 } \over {2g}}
$${latex}

where
* h ~l~ the difference in head loss between the maximum CDC head loss and the actual head loss in the flexible dosing tube
* K ~DoseOrifice~ is the required minor loss coefficient through the orifice
* V ~DoseTube~ is the velocity in the dosing tube


This head loss is equal to head loss in the vena contracta. Head loss in the vena contracta is modeled by the equation:

{latex}$$h_l  = K_{Exit} {{V_{VenaContracta}^2 } \over {2g}}$${latex}


where
* h ~l~ is the head loss
* {latex}$$ K_{Exit}$${latex} is the minor loss coefficient from an exit to the atmosphere
* V ~VenaContracta~ is the velocity in the orifice vena contracta


{latex}$$ K_{Exit}$${latex} is equal to one. The flow rate through the dosing tube is known and velocities in the vena contracta can be found using mass conservation:

{latex}$$A_{DoseTube} V_{DoseTube}  = K_{Orifice} A_{DoseOrifice} V_{DoseOrifice} $${latex}

where
{latex}$$ K_{Orifice}$${latex} is the orifice vena contracta coefficient equal to 0.63. Using the three equations above a relationship for the velocities can be found:

{latex}$$
K_{DoseOrifice}  = \left[ {{1 \over {K_{Orifice} }}\left( {{{V_{DoseTube} } \over {V_{DoseOrifice} }}} \right)^2 } \right]^2 
$${latex}

The chemical dose flow rate is not exactly proportional to the plant flow rate due to different exponential relationships between flow and head loss for the major losses. These differences arise from two sources. The most significant difference occurs when the flow in the dosing tube is laminar and thus the flow rate is proportional to the major head loss rather than to the square root of the head loss. The other source of error occurs for transitional flow where the friction factor decreases with increasing Reynolds number. 	
{float:right|border=2px solid black|width=400px}
!Chem dose error (QPlant).png|width=400px,align=top!
h5. Figure 2: Dosing error from the nonlinear CDC for two maximum flow rates and for two chemical doses. The conditions were: 1 m long dosing tube, CDC head loss of 50 cm, major losses constrained to less than 10% of total head loss, stock concentration of 120 g/L, maximum chemical dose of 60 mg/L, and minimum plant flow that could be measured by the plant flow orifice was 20%. The [MathCAD file is attached|^Nonlinear CD.xmcd].
{float}
The error due to the major loss contribution to the head loss is shown in figure 2. The error is most significant for low chemical flow rates. The error can be reduced by decreasing the major losses, but that requires the use of larger dosing tubes.

The nonlinear relationship between flow and head loss makes it more difficult to accurately control the chemical dose when the dose is low. \\
{latex}$${{HL_{Cdc_{Min} } } \over {HL_{Cdc_{\max } } }} = \left( {{{Q_{Cdc_{Min} } } \over {Q_{Cdc_{\max } } }}} \right)^2 $${latex}\\
For this reason it is recommended that the total head loss range be increased to approximately 50 cm for the nonlinear CDC. For a chemical dose that is 10% of the maximum chemical dose the head required by the dosing tube is 1% of the maximum head loss (0.5 cm). Maintaining a positioning error of less than 0.5 cm may be difficult and would require a large float to minimize errors due to changes in moment caused by the dosing tube. The CDC lever must also be accurately calibrated to minimize errors at low chemical dosing rates. Thus the maximum head loss for the CDC should be at least 50 cm.
\\

h4. Viscosity of Alum
{float:right|border=2px solid black|width=400px}
[!alum viscosity.png|width=400px,align=top!|^Density and Kinematic viscosity of Alum.xmcd]
h5. Figure 3: Viscosity of Alum.
{float}
The [viscosity of alum|^Density and Kinematic viscosity of Alum.xmcd] is only slightly larger than that of water for concentrations used in stock solutions (Figure 3). At concentrations above 550 g/L the viscosity increases rapidly and thus concentrations above 550 g/L should be avoided when using hydraulic flow control.



h4. Lever Arm and Float

Since the head loss range required to accurately control the chemical dose at low chemical dosages is at least 50 cm, the length of the lever arm must be sufficient to handle that vertical motion.  

Refer to [LeverArmLength|^LeverArmLength.xmcd] to determine a lever arm length and the maximum angle to use for a given elevation difference

The size of the float can be determined using a moment balance around the pivot of the lever arm. This is to ensure that a change of 20 cm in head in the entrance tank will cause a similar change in the relative height of the float. The float was sized using the same float sizing algorithm used by the linear CDC. For flows between 600 and 25,000 L/min the float diameter ranged between 6 and 16 in. 

h4. Flow Control module

{float:left|border=2px solid black|width=200px}
!NonlinearFCM.jpg|thumbnail,align=top!
h5.  Figure 4: Flow Controller for Nonlinear module
{float}

When choosing what size float valve to use, the constraints are the maximum flow rate through the valve, the allowable head loss through the valve, and the size of the valve orifice. The allowable head loss through the valve is kept small to avoid excessively elevated stock tanks for alum and chlorine. Various valve orifices sizes are [available| http://floatvalve.com/float-valves.html]. Note that the inlet sizes given (a pipe thread size) are not the orifice dimension.

h4. Functional Range

The functional range is limited by the float valve orifice. The [largest float valve manufactured by Kerick Valve| http://floatvalve.com/ps150ss-detail.html] has an orifice of 2.54 cm (1 inch). With a head loss of 30 cm the flow rate would be 0.77 L/s and the corresponding plant flow rate could be as high as 6000 L/s.

through the [Rapid Mix Tube| Rapid Mix Tube] and the alum is dosed directly into the tube. An orifice is located in the tube to generate small-scale mixing. 
The relationship between flow rate and head loss is governed by the orifice equation:
{latex}$$ Q_{Plant}  = K_{orifice} \sqrt {2gh_{EtOrifice} } $${latex}

where
* {latex}$$ Q_{Plant}$${latex} is the plant flow rate
* {latex}$$ h_{EtOrifice} $${latex} is the height of water above the entrance tank orifice

The CDC uses a lever arm with a float and counterweight to relate the dosing to the changes in the entrance tank water level, which is a function of the flow rate. 

to relate head above the centerline of the rectangular plant entrance orifice to head in the dosing orifice. This means that the available head for the dosing orifice is the same as the head controlling the plant flow rate. The increase in head links the chemical flow rate to the plant flow rate and the chemical dose will be constant as plant flow varies as long as the exponent of the head is the same for both the plant flow and the chemical flow.

The dosing tube must be designed to minimize major losses so that the major losses that deviate from the {latex}$$V = \sqrt {2gh}$${latex} relationship do not cause excessive errors. The deviation from {latex}$$V = \sqrt {2gh}$${latex} is especially significant when the flow through the dosing tube becomes laminar. The dosing tube must be flexible to accommodate the lever arm motion and dose adjustment. There will be two dosing tubes from the constant head tank to the level arm (one for each [scale | Dual Scale System] and one tube from the lever arm to the rapid mix tube. 

h3. Methods

h4. Designing the Dual-Scale Lever Arm and Float

A [dual scale system| Dual Scale System]on the lever arm was designed to increase accuracy of dosing at lower chemical concentrations.The scale is non-linear to match the Q=sqrt h relationship on either side of the lever arm.   


h4. Designing Orifice Sizes 
The [dosing orifices|| Orifice Sizes] were designed to produce the difference in head loss between the maximum CDC head loss and the actual head loss in the flexible dosing tube:

{latex}$$
h_l  = K_{DoseOrifice} {{V_{DoseTube}^2 } \over {2g}}
$${latex}

where
* h ~l~ the difference in head loss between the maximum CDC head loss and the actual head loss in the flexible dosing tube
* K ~DoseOrifice~ is the required minor loss coefficient through the orifice
* V ~DoseTube~ is the velocity in the dosing tube

h4. Designing a Prototype Doser Frame 
AutoCad was used to design a [prototype doser frame|Prototype Doser Frame]. 80/20 plug-ins were used to facilitate modeling and eventual full-scale construction of the dosing system. 

h4. Designing the Rapid Mix Tube 
A [rapid mix tube|Rapid Mix Tube] was designed for large-scale and small-scale mixing of alum with water before flocculation.  

h4. Constructing a Small-Scale Model of the Plant
A model of the plant will be constructed using acrylic plastic for use in educational and promotional presentations.