...
Let's create lines after heated section
Insert > Location > Line
Name it "Postheat 1" and click OK. On the lower left panel, you will see Details of Postheat 1. Enter the following coordinates.
Point 1 (4.27,0,0)
Point 2 (4.27,0.0294,0)
Enter 50 for Samples. (This will be the number of sample points used when plotting data) Click Apply.
Create Postheat 2.
Insert > Location > Line
Name it "Postheat 2" and click OK. On the lower left panel, you will see Details of Postheat 2. Enter the following coordinates.
Point 1 (5,0,0)
Point 2 (5,0.0294,0)
Enter 50 for Samples. Click Apply.
Continue the same step for creating line Outlet (x=6.096m)
Check that you have the following under Outline.
...