Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Upon observing that waterfalls, like the one found in the LFOM, created the ideal fluid dynamic conditions for air entrainment; the second half of the research focused on retrofitting the LFOM at current operational AguaClara plants. **** editting:retrofitting AguaClara's designs so that no air entrainment occurs in the entrance tank and rapid mix chamber by eliminating waterfalls and or implementing hydraulic jumps.********The four main designs that were suggested either used a submerged orifice, a vertical surface area or an inclined plane to decrease the velocity of the incoming water through the LFOM.

Introduction and Objectives

...