With our initial test of the 3cm pipe, there was no noticeable change in the amount of bubbles formed under the LFOM. For the 5cm-diameter pipe we found a drastic reduction in the amount of bubbles formed under the LFOM. Keeping the pipe in for 5 minutes showed no signs of overflowing the LFOM or even raising the water level, so we can assume that 5cm is a possible solution. Finally, we tested a 6cm pipe for 5 minutes in the LFOM. We noticed that the water level outside the LFOM rose slowly throughout the 5 minutes until the water flowed over the top of the LFOM. This clearly meant that the 6cm pipe was too big, and was causing a backup of water within the LFOM. (attach mathcad sheet here)

We were able to document results for each variation of the designs visually with photographs and short movies on cameras.

...