- Work with the team Honduras to evaluate the current linear CDCs at the Tamara and Cuatro Comunidades.
- Need to make the nonlinear mathCAD MathCAD file more robust.
- Currently input plant flow rate and actual plant flow rate are not the same in the algorithm.
- Extend the range of the design below 6000 L/min. The doser works best at high chemical flow rates with a wide tube. Is there a way to increase chemical flow rates for plant flows below 6000 L/min without overdosing alum? ( e.g. decrease stock concentration- might create huge chemical stock tank however)
...
- Modify the rapid mix MathCAD so that the flocculator first section baffle spacing is no longer a constraint on the orifice collector channel width. In other words modify the code so that an aspect ratio (channel width/water depth) is specified rather a fixed depth.
Linear Chemical Dose Controller
...
- Write and edit paper documenting all the research into the Linear Chemical Dose Controller. The manuscript needs to be suitable for publication. All drafts are attached to the Wiki.
- Consult with Monroe regularly to ensure completion of manuscript by end of semester. Complete multiple drafts for review and repeat .
- Perform experiments to collect any data that is missing from the paper.
- Repeat any experiments that may need to be run again to ensure accuracy.