Preliminary experiments were conducted to determine the appropriate time interval for the flow and increment states. These experiments consisted of running the system for an exorbitant length of time to identify the timeframe necessary to reach constant effluent turbidity. Ultimately, we decided to form the floc blanket for three hours; run each flow rate for six hours; stop effluent flow for ten seconds between flow rates; and allow about twenty minutes for the floc blanket to grow from its low to high depths. The floc blanket was reformed each time a new diameter was tested.
Results
Table 1. Results
...