Q = 100 L/min
K.baffle = 4
Π.cell = 1
w = .305 m
b = various spacings (in)

b (m)

ε (mW/kg)

.0051 49

12.099 275

.076 9

2.699 425

.102

3 .069 767

.127

1 .257 314

.152

0.606 152

.178

0.327 082

.203

0.192 048

Outcomes
  • Have range of values of spacings to be tested with adjustable baffle system to find an optimal energy dissipation rate. With both sets of baffles done and a range of dissipation rates to test we can turn on the plant and begin taking turbidity profiles.

...