Q = 100 L/min
K.baffle = 4
Π.cell = 1
w = .305 m
b = various spacings (in)
b (m) | ε (mW/kg) |
.0051 49 | 12.099 275 |
.076 9 | 2.699 425 |
.102 | 3 .069 767 |
.127 | 1 .257 314 |
.152 | 0.606 152 |
.178 | 0.327 082 |
.203 | 0.192 048 |
Outcomes
- Have range of values of spacings to be tested with adjustable baffle system to find an optimal energy dissipation rate. With both sets of baffles done and a range of dissipation rates to test we can turn on the plant and begin taking turbidity profiles.
...