Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

The output data for any element type is broken down into item groups with SMISC being one of the groups (SMISC stands for "Summable Miscellaneous" items). Each item within a group such as SMISC has an identifying "sequence" number. So, as per the above entry in Table 1.2, MFORX is an item in the SMISC group with a sequence number 1. In effect, it's entry #1 in the SMISC group for the LINK1 element.

Minimize the help window. To list MFORX values, select:

Main Menu > General Postproc > List Results > Element Solution

Under Element Solution, select Miscellaneous Items > Summable data (SMISC,1). Since MFORX is sequence number 1 in the SMISC group, enter 1 next to Sequent Sequence number SMIS in the editable field. Click OK. Click OK in the List Element Solution window.

This brings up a window with the axial forces in the elements. Positive values indicate tension and negative values compression.

...