You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 38 Next »

Author: Rajesh Bhaskaran, John Singleton, Cornell University

Problem Specification
1. Pre-Analysis & Start-up
2. Geometry
3. Mesh
4. Setup (Physics)
5. Solution
6. Results
7. Verification and Validation

Under Construction

This page of this tutorial is currently under construction. Please check back soon.

Useful Information

Click here for the FLUENT 6.3.26 version.

Step 4: Setup (Physics)

Your current Workbench Project Page should look comparable to the following image. Regardless of whether you downloaded the mesh and geometry files or if you created them yourself, you should have checkmarks to the right of Geometry and Mesh.



Next, the mesh and geometry data need to be read into FLUENT. To read in the data (Right Click) Setup > Refresh in the Workbench Project Page as shown in the image below.



After you click Update, a question mark should appear to the right of the Setup cell. This indicates that the Setup process has not yet been completed.

Launch Fluent

Double click on Setup in the Workbench Project Page which will bring up the FLUENT Launcher. When the FLUENT Launcher appears change the options to "Double Precision", and then click OK as shown below.The Double Precision option is used to select the double-precision solver. In the double-precision solver, each floating point number is represented using 64 bits in contrast to the single-precision solver which uses 32 bits. The extra bits increase not only the precision, but also the range of magnitudes that can be represented. The downside of using double precision is that it requires more memory.


Click Here for Higher ResolutionVisit page in new window


Twiddle your thumbs a bit while the FLUENT interface starts up. This is where we'll specify the governing equations and boundary conditions for our boundary-value problem. On the left-hand side of the FLUENT interface, we see various items listed under Problem Setup. We will work from top to bottom of the Problem Setup items to setup the physics of our boundary-value problem. On the right hand side, we have the Graphics pane and, below that, the Command pane.

Check and Display Mesh

First, the mesh will be checked to verify that it has been properly imported from Workbench. In order to obtain the statistics about the mesh (Click) Mesh > Info > Size, as shown in the image below.



Then, you should obtain the following output in the Command pane.



The mesh that was created earlier has 3,000 elements(50 x 60). Note that in FLUENT elements are called cells. The output states that there are 3,000 cells, which is a good sign. Next, FLUENT will be asked to check the mesh for errors. In order to carry out the mesh checking procedure (Click) Mesh > Check as shown in the image below.



You should see no errors in the Command Pane. Now, that the mesh has been verified, the mesh display options will be discussed. In order to bring up the display options (Click) General > Mesh > Display as shown in the image below.



The previous step should cause the Mesh Display window to open, as shown below. Note that the Named Selections created in the meshing steps now appear.


Click Here for Higher ResolutionVisit page in new window


You should have all the surfaces shown in the above snapshot. Clicking on a surface name in the Mesh Display menu will toggle between select and unselect. Clicking Display will show all the currently selected surface entities in the graphics pane. Unselect all surfaces and then select each one in turn to see which part of the domain or boundary the particular surface entity corresponds to (you will need to zoom in/out and translate the model as you do this). For instance, if you select far_field, inlet, and plate and then click Display you should then obtain the following output in the graphics window.



Now, make sure all 5 items under Surfaces are selected. The button next to Surfaces selects all of the boundaries while the button deselects all of the boundaries at once. Once, all the 5 boundaries have been selected click Display, then close the Mesh Display window. The rectangle displayed in the graphics window corresponds to our solution domain. Some of the operations available in the graphics window to interrogate the geometry and mesh are:

Translation: The model can be translated in any direction by holding down the Left Mouse Button and then moving the mouse in the desired direction.

Zoom In: Hold down the Middle Mouse Button and drag a box from the Upper Left Hand Corner to the Lower Right Hand Corner over the area you want to zoom in on.

Zoom Out: Hold down the Middle Mouse Button and drag a box anywhere from the Lower Right Hand Corner to the Upper Left Hand Corner.

Use these operations to zoom in and interrogate the mesh.

Define Solver Properties

In this section the various solver properties will be specified in order to obtain the proper solution for the flat plate boundary layer flow. First, the Energy Model parameters will be specified. In order to open the Energy Model Options Models > Energy-Off > Edit..., as shown in the following image.


Click Here for Higher ResolutionVisit page in new window


For incompressible flow, the energy equation is decoupled from the continuity and momentum equations. We need to solve the energy equation only if we are interested in determining the temperature distribution. We will not deal with temperature in this example. So leave the Energy Equation set to off and click Cancel to exit the menu. Next, the Viscous Model parameters will be specified. In order to open the Viscous Model Options Models > Viscous - Laminar > Edit..., as shown below.


Click Here for Higher ResolutionVisit page in new window


By default, the Viscous Model options are set to laminar, so no changes are needed. Click Cancel to exit the menu.

Define Material Properties

Now, the properties of the fluid that is being modeled will be specified. The properties of the fluid were specified in the Problem Specification section. In order to create a new fluid (Click) Materials > Fluid > Create/Edit... as shown in the image below.


Click Here for Higher ResolutionVisit page in new window


In the Create/Edit Materials menu set the Density to 1kg/m^3 (constant) and set the Viscosity to 2e-3 kg/(ms) (constant) as shown in the image below.


Click Here for Higher ResolutionVisit page in new window


Click Change/Create. Close the window.












Problem Setup > Materials

Double click air or select it and click Create/Edit. Make sure air is selected under Fluid Materials. Set Density to 1.00 and Viscosity to 1e-4 so that we can get Re of 1e4.


Higher Resolution Image
Click Change/Create.

Define Boundary conditions

Problem Setup > Boundary Conditions

Set the inlet boundary type to velocity-inlet. Then click Set...Set the velocity magnitude to 1 m/s. Set the outlet type to pressure-outlet boundary. Use gauge pressure of 0 Pa.Use the default value of wall for the center line. Set the far field to symmetry boundary type. Symmetry boundary condition means that the component normal to the wall is zero.

Problem Setup > Boundary Conditions

 > Operating Conditions


 
Use the default value. Click OK.

Go to Step 5: Solution