Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Click on Physics in the workflow. In the Physics template input a Frequency of 200Hz.

 Image RemovedImage Added

Specify Material

Click on Add, next to Material Assignments > Material Assignment > Air (Material Samples). Next, click on body selection in top right corner. Select the Surrounding region and click Add. This assigns air to the surrounding region.

Image RemovedImage Added

Repeat the above steps except assign Copper (Material Sample) to the coil and Aluminum Alloy (Material Sample) to the plate. In order to make this process easier. Right click on surrounding region and select Hide Body.  


Image RemovedImage Added

Boundary Conditions / Forces

Since a current is running through the copper coil, a current condition will need to be created. Right click > Add > Electromagnetic Conditions > Current. Then select the face below for the Cross-Sectional face or body.

Image RemovedImage Added

Input an Operating Current of 2.742 Amps and 1000 for Number of Conductors.

Image RemovedImage Added

Finally, a Skin Depth Resolution needs to be specified. Right click, and select Fix. Select the top face of the plate and move the Resolution slider up to Fine. The Skin Depth Resolution will automatically refine the mesh where the eddy currents occur.

Image RemovedImage Added

Image RemovedImage Added


Go to Step 4: Numerical Solution/Results

Go to all ( ANSYS or FLUENT) AIM Learning Modules