Include Page
Stepped Shaft - Panel
Stepped Shaft - Panel
Include Page
ANSYS Google Analytics
ANSYS Google Analytics

Pre-Analysis & Start-Up

Pre-Analysis

It is recommended that you make some back-of-the-envelope estimates of expected results before launching into your computer solution. Here

for which the following formula for the axial stress concentration factor, K, holds (Roark’s Formulas for Stress and Strain, Warren C. Young and Richard G. Budynas, 2002):

We'll compare the above axial stress concentration factor to the value obtained from ANSYS.

Start-Up

Launch ANSYS Workbench and start a "Static Structural" analysis in the project page as shown in the video below.

HTML
<iframe width="600" height="338" src="//www.youtube.com/embed/OdS706NgClY?rel=0" frameborder="0" allowfullscreen></iframe>


Go to Step 2: Geometry

Go to all ANSYS Learning Modules