Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Migrated to Confluence 5.3
Include Page
ANSYS Google Analytics
ANSYS Google Analytics
Include Page
3D Conduction - Panel
3D Conduction - Panel

3D Conduction

Created using ANSYS 13.0

Problem Specification

This is a design-problem simulation. We have a Platinum micrometer bridge deposited onto a Silicon wafer (with a Silicon Dioxide insulation layer) submersed in a pool of stagnant water.

The small platinum bridge will have electricity passing through it, generating 4 Watts of heat uniformly across it. We need to determine how long we can keep the electricity active before the hottest portion of the platinum becomes 570 K.

Notice that this bridge has 2 planes of symmetry, thus we need only model 1/4 of the body! This is definitely something we need to take advantage of to ease the computationally intensive project.



Go to Step 1: Pre-Analysis & Start-Up

Go to all ANSYS Learning Modules