ANSYS Google Analytics
ANSYS Google Analytics
Include Page
High Resolution FE Model of Bone - Panel
High Resolution FE Model of Bone - Panel

Verification & Validation

Recall from Pre-analysis, the equivalent stiffness of the bone model is:

Image RemovedImage Added

ANSYS gives a stiffness of 2629.14 33 MPa for the bone model. According to Professor Hernandez, the stiffness for this model is about 24MPa. There is an 8% 22% error and the source of the error is currently being determined.