Metrology & Post Processing

Aspect Ratio & Selectivity

Model UV Curing

  • Parts, particularly shell and scaffold components, may require a UV cure after development. 
    • Shell and scaffold parts contain uncured resin within solid walls. Failure to UV cure will result in weak parts and may leak resin.
  • The resin's highest sensitivity is to 405 nm UV, however broad spectrum UV curing stations may also work.
    • NOTE: The resin may burn or become distorted with UV power densities above 7 W/m2
    • Typical maximum cure depth is 2.5 mm
    • Recommended exposure time is 1-15 minutes, dependent on part geometry
  • Alternately, parts may be heat cured. IP-S cures in 5 minutes at 190°C and 17 h at 140°C. Care must be taken to slowly heat samples; thermal shock may break your part off the substrate prematurely. IP-DIP and IP-L cannot be heat cured.

...